The article proposes a technique of blast-wave-pressure-express evaluation at
a charge detonation inside a working space of the multi-camera container confined in
an envelope filled with a multi-phase medium. The technique is based on a quasi-stationary
symmetrical model of the container deformation. Calculated values of shock wave
overpressures have been compared with experimentally obtained data for TNT charge
detonations in the working space of various blast liquid inhibitors.
Keywords: : shock wave overpressure; multi-camera container deformation; quasi-stationary symmetrical model |
full paper (pdf, 1392 Kb)